-   Pressemitteilungen Performance3 - the new generation. AERZEN baut Technologiekonzept aus.

Lastwechsel exakt bedienen: Neue Gebläse-generationen, gesteigerte Effizienz.

[Translate to German:]
[Translate to German:]

Das innovative Performance³-Konzept von AERZEN gilt als die wohl effizienteste, leistungsstärkste und flexibelste Technologielösung zur bedarfsgerechten Sauerstoffversorgung in Klärbecken. Jetzt geht der Gebläse- und Verdichterspezialist mit neuen Gebläsegenerationen der Baureihen Delta Hybrid und Aerzen Turbo den nächsten Schritt – für noch mehr Effizienz im Belebungsbecken.

[Translate to German:]

[Translate to German:]

Depending on the region, time of day and season, as well as the amount of precipitation and pollution load, municipal or industrial biological wastewater treatment plants experience different degrees of pollution and strong fluctuations within the load profiles. Due to this fluctuating load profile, the air demand in the aeration tank changes continuously. With the efficiency concept Performance³, AERZEN offers a unique strategy for the exact control of the load changes and thus an optimal solution for an energy-efficient oxygen supply. Thanks to the possible combination of different technologies, sizes and design points, the blower and compressor specialist achieves individual blower solutions which allow energy savings of up to 30%. The current technological progress in the Delta Hybrid and Aerzen Turbo series ensures that further performance and efficiency potentials can be maximised.

IDEAL COMBINATION OF TECHNOLOGICAL ADVANTAGES

Whether Delta Blower, screw blower, Delta Hybrid or Aerzen Turbo: each blower technology has individual strengths, but also physical limits. The key to success is the combination of the technologies: in this way, the respective technological strengths can be combined and possible weaknesses eliminated.

Thus, the turbo blower offers above-average energy efficiency at the design point and is thus predestined to handle the base load. However, the control range of turbo machines is physically limited between 35% and 100 %. Thus, the efficiency decreases in part-load operation. This is the strength of rotary lobe machines, which are characterised by a controllability of 25% to 100 % and an almost constant efficiency even in partial load operation. The innovative screw blowers and the robust positive displacement blowers are therefore perfectly suited for generating peak or off-peak load requirements. Depending on the system configuration and load, these three technologies can be switched in interaction or as individual solutions to achieve maximum efficiency for the entire load demand based on their focus.

TECHNICALLY AND ECONOMICALLY THE OPTIMUM

During the development of the new Delta Hybrid and Aerzen Turbo packages, the focus was mainly on a further increase of the energy efficiency and thus the consistent optimisation of the cost balance. These advantages are also reflected in the Performance³ concept. The result: highest energy savings with best control range and lowest investment volume. Furthermore, depending on the system, the payback period is less than two years.

Ihr Ansprechpartner

Sebastian Meißler Marketing Communication & Branding
Languages: German, English
Telephone
+49 5154 81 9970
Fax
+49 5154 81 719970
E-mail
Kontakt aufnehmen
Aerzener Maschinenfabrik GmbH (Headquarter)
Reherweg 28
31855 Aerzen
Telephone
+49 5154 81-0
Fax
+49 5154 81-9191
E-mail
Kontakt aufnehmen

Weiterführende Downloads